12
FRONT CONTROL PANEL
1. Air Pressure Gauge: Indicates the PSI reading for the
downward pressure of the top main roller. The
standard setting for the normal operation is 35-55
PSI.
2. Air Regulator Knob: Adjusts the downward pressure
of the top roller. Turn clockwise to increase the
pressure.
3. Roller Up/Down Switch (Front, Top): Press up to
raise the roller. Press down to lower the roller.
4. Cooling Fan On/Off Button: Turns On/Off the
cooling fan. The corresponding LED will be lit when
the fan is ON.
5. Reset Button: Press this button to reset the material
total usage counter to zero. Totalizer Display must
be showing to be able to zero out.
6. Ratemeter /Totalizer Button: Pressing this button
will toggle between the roller speed readout or total
material usage. Press this button to track and display
the total number of feet or meters run in a given
period, which can help to monitor film usage. The
total will be stored even after the laminator is turned
off, and adds to the total whenever the bottom main
roller is turning. The corresponding LED will be lit
when the totalizer is being used.
7. Ratemeter/Totalizer Readout: Displays the rate of
speed of the main rollers in either feet or meters per
minute, or displays the total number of feet or
meters run in a given period.
8. Top Roller Temperature Increase Button: Press this
button once to view the temperature set point. Press
and hold the button to raise the top roller
temperature.
9. Top Roller Temperature Readout: Displays both the
set and actual temperature of the top roller.
10. Top Roller Temperature Decrease Button: Press this
button once to view the temperature set point. Press
and hold the button to lower the top roller
temperature.
11. Bottom Roller Temperature Increase Button: Press
this button once to view the temperature set point.
Press and hold the button to raise the bottom roller
temperature.
12. Bottom Roller Temperature Readout: Displays both
the set and actual temperature of the bottom roller.
13. Bottom Roller Temperature Decrease Button: Press
this button once to view the temperature set point.
Press and hold the button to lower the bottom roller
temperature.
14. Bottom Roller Temperature On/Off Button: Turns
On/Off the bottom roller heater. The corresponding
LED will be lit when the heater is ON.
15. Top Roller Temperature On/Off Button: Turns
On/Off the top roller heater. The corresponding
LED will be lit when the heater is ON.
16. Stand-by On/Off Switch: Press this switch up to
turn on the laminator. Press this switch down to put
it on Standby. In Standby, the laminator power is still
on, but all functions are disabled.
Figure 5. Front Control Panel
0
20
40
60
80
100
120
140
160
2
3
4
5
7
6
10
9
16
11
15
12
8
13
14
1