SEAL Image 6500 Spécifications Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10
SAFETY FEATURES
The SEAL
®
Image
®
6500 Laminator is
designed with safety and protective devices
with the user’s safety of utmost
consideration. However, following safe
operating guidelines is still the responsibility
of the operator.
Hand-Operated Emergency Stop Buttons
Emergency Stop buttons are located on each side of the
cabinets for easy access. Once pressed, they immediately
cease the laminator’s operation and raise the rollers. Use
these only in the case of an emergency or you may
damage an image during a process.
NOTE: Once pressed, these buttons lock and must
be turned clockwise to reset.
After resetting the Emergency Stop button, you must
turn the heaters back on (if being used), and push one
of the Motor Direction Switches to begin processing
again.
Foot-Operated Emergency Tap Switches
Located on both sides of the laminator, pressing on
these tap switches will immediately cease the laminator’s
operation and raise the rollers.
Covered Foot Switches
One on each side of the laminator allows for complete
user control when initially feeding an image into the nip
or for feeding a delicate image through the rollers. The
cover prevents accidentally stepping on the foot switch
and starting the laminator.
WARNING! The laminator operation will cease
immediately when the photo electric eyes, set
directly in the path of the front of the rollers, are
blocked. On Domestic version laminators, the foot
switch overrides the photoelectric eyes. When the
photo eye is blocked, a BUZZER sounds, warning
of close proximity to the nip. When the photo eye is
blocked, the laminator runs in slow mode at a
speed of 2.0 ft (0.6m) per minute. Use care to keep
hands clear of the rollers while using the foot
switch to prevent possible injury.
Photo Electric Safety Eyes
A light beam path set directly in front and back of the
laminating roller openings prevents foreign objects from
passing between the rollers. (The eyes are set for use at
the factory and checked by the service representative.)
Locking Cabinets
The cabinets that house the inner workings of the
laminator include locks that maintenance or safety
personnel can open only with the supplied keys.
WARNING! Use of the inside of the cabinets for
storage may cause possible personal injury and/or
damage to the inner workings and will void the
warranty.
Door Interlock
Located on the left side cabinet (facing front of
laminator), it automatically shuts the laminator power
off when the door interlock switch is turned to the OFF
position.
WARNING! For any servicing, ALWAYS turn the
door interlock switch to the OFF position and the
main power circuit breaker off before opening the
side cabinets.